i-PDM Comparison

i-PDM Comparison i-PDM Comparison

The table below illustrates the differences between range of Power Distribution Modules.

Please contact us for any advice.

i-PDM Lite i-PDM Core i-PDM Plus
Summary / Key Features Entry-level model. Input & Output only. Mid Tier model. Input & Output with single CAN Bus interface. High End Model. Input & Output with dual CAN Bus interface and Wi-Fi connect-ability.
Construction Glass Fibre Reinforced Plastic Glass Fibre Reinforced Plastic Glass Fibre Reinforced Plastic
Size 133x119x36mm 200x160x54mm 200x160x54mm
Weight 250g 615g 660g
Operating Temperature -55°C to 90°C (-67°F to 194°F) -55°C to 90°C (-67°F to 194°F) -55°C to 90°C (-67°F to 194°F)
Physical Connectors 2 x Deutsch DT 12-Pin 4 x Deutsch DT 12-Pin 4 x Deutsch DT 12-Pin
Software Connection USB Mini-B USB Mini-B USB Mini-B
Wi-Fi (Client & Access point)
Update Rate Up to 800Hz Up to 800Hz Up to 1000Hz
Safety Features Global Reset
Global Cut-off
Input voltage protection -24V to 40V
Output over-current
Output over-temperature
Output reverse polarity protection
Global Reset
Global Cut-off
Input voltage protection -24V to 40V
Output over-current
Output over-temperature
Output reverse polarity protection
Global Reset
Global Cut-off
Input voltage protection -24V to 40V
Output over-current
Output over-temperature
Output reverse polarity protection
Inputs 10 16 16
Input Measurement Range

*Independent of the battery voltage

0V-6V 0V-6V 0V-28V
Input Measurement Resolution 10-Bit, or 0.01V 10-Bit, or 0.01V 10-Bit, or 0.01V
Outputs 10 High sided
80A peak, 20A continuous.
15 High sided.
80A peak, 20A continuous.
19 High sided
80A peak, 20A continuous.4 Hybrid High/Low side
80A peak, 20A continuous.2 reverse current protected
80A peak, 20A continuous.
Maximum Combined Output 150A 180A 180A
CAN Bus Connection No Yes (x1) Yes (x2)
CAN Keypad N\A Yes (x2) Yes (x4)
CAN Termination Resistors N/A No Software configurable
Additional Features Data logging
Input hysteresis
Soft Start
PWM
Over-current detection
Logical operators
Maths channels
Counters
Data logging
Input hysteresis
Soft Start
PWM
Over-current detection
Logical operators
Maths channels
Counters
Gyroscope
Accelerometer
Data logging
Input hysteresis
Soft Start
PWM
Over-current detection
Logical operators
Maths channels
Counters
3-axis rotational measurement
Gyroscope
Accelerometer